Resources
Apollo EMS – Compatibility list
Apollo EMS is an open, manufacturer-independent energy management system for commercial and industrial sites. Devices connect via Modbus TCP/RTU, OPC UA, SunSpec, OCPP and REST API. We usually connect devices that are not listed as part of a project – just ask at hello@apollo-gs.com.
- Field-tested
- running in sites with Apollo EMS
- Supported
- integration available, commissioned in the project
- In preparation
- integration in progress
| PV inverters | any manufacturer | Inverters compliant with SunSpec | Modbus TCP, SunSpec | Supported |
| PV inverters | Fronius | Inverters with SunSpec | Modbus TCP/RTU, SunSpec | Supported |
| PV inverters | GoodWe | GW5-ET, GW8-ET, GW10-ET | on request | Supported |
| PV inverters | KACO | blueplanet 15.0 TL3 and 20.0 TL3 | Modbus TCP/RTU, SunSpec | Supported |
| PV inverters | KACO | blueplanet 3.0 TL3 – 10.0 TL3 | Modbus TCP/RTU, SunSpec | Supported |
| PV inverters | KACO | blueplanet hybrid 10.0 TL3 | proprietary | Supported |
| PV inverters | KDK | Inverters | Modbus TCP/RTU, SunSpec | Supported |
| PV inverters | SMA | Sunny Tripower 15000TL, 20000TL, 25000TL | on request | Supported |
| PV inverters | SMA | Sunny Tripower 8.0 and 10.0 | on request | Supported |
| PV inverters | Solar-Log | PV inverters via Solar-Log | on request | Supported |
| PV inverters | SolarEdge | Inverters | on request | Supported |
| Battery storage and BMS | ADS-TEC | StoraXe | on request | Supported |
| Battery storage and BMS | Bosch | BPT-S 5 Hybrid | on request | Supported |
| Battery storage and BMS | FENECON | Commercial 30 | on request | Supported |
| Battery storage and BMS | FENECON | Commercial 50 | on request | Supported |
| Battery storage and BMS | FENECON | Home | on request | Supported |
| Battery storage and BMS | FENECON | Home Battery | on request | Supported |
| Battery storage and BMS | FENECON | Industrial | on request | Supported |
| Battery storage and BMS | FENECON | Pro AC GW | on request | Supported |
| Battery storage and BMS | FENECON | Pro Hybrid 10 | on request | Supported |
| Battery storage and BMS | FENECON | Pro Hybrid GW | on request | Supported |
| Battery storage and BMS | GoodWe | GW5-BT, GW8-BT, GW10-BT | on request | Supported |
| Battery storage and BMS | KACO | blueplanet gridsave 50.0 TL3 | Modbus TCP/RTU, SunSpec | Supported |
| Battery storage and BMS | KACO | blueplanet gridsave 92.0 TL3 | Modbus TCP/RTU, SunSpec | Supported |
| Battery storage and BMS | KOSTAL | PIKO | on request | Supported |
| Battery storage and BMS | Maschinenfabrik Reinhausen | GRIDCON PCR | on request | Supported |
| Battery storage and BMS | REFU | REFUstor 88K | on request | Supported |
| Battery storage and BMS | Sinexcel | Battery inverters | on request | Supported |
| Battery storage and BMS | SMA | Sunny Island 6.0H | on request | Supported |
| Battery storage and BMS | Soltaro | Battery Racks | on request | Supported |
| Battery storage and BMS | Tesla | Powerwall 2 | on request | Supported |
| Battery storage and BMS | Voltfang | Battery storage | on request | Field-tested |
| Charging infrastructure (wallboxes and DC chargers) | ABL | eMH3 | on request | Supported |
| Charging infrastructure (wallboxes and DC chargers) | any manufacturer | Wallboxes and DC chargers with OCPP, via Apollo CPMS | OCPP 1.6, OCPP 2.0.1 | Supported |
| Charging infrastructure (wallboxes and DC chargers) | go-e | go-eCharger HOME+ | on request | Supported |
| Charging infrastructure (wallboxes and DC chargers) | Hardy Barth | cPH1 | on request | Supported |
| Charging infrastructure (wallboxes and DC chargers) | Hardy Barth | cPμ2 | on request | Supported |
| Charging infrastructure (wallboxes and DC chargers) | IES Synergy | Keywatt DC24 | on request | Supported |
| Charging infrastructure (wallboxes and DC chargers) | KEBA | KeContact P30 c-series | OCPP 1.6 via Apollo CPMS | Field-tested |
| Charging infrastructure (wallboxes and DC chargers) | KEBA | KeContact P30 x-series | OCPP 1.6 via Apollo CPMS | Field-tested |
| Heat pumps and heating | any manufacturer | Heat pumps with Modbus interface | Modbus TCP/RTU | Supported |
| Heat pumps and heating | any manufacturer | Heat pumps with SG Ready input | SG-Ready | Supported |
| Meters and measurement | any manufacturer | Meters compliant with SunSpec | Modbus TCP, SunSpec | Supported |
| Meters and measurement | ARTEMES | AM-2 | on request | Supported |
| Meters and measurement | Carlo Gavazzi | EM300 | on request | Supported |
| Meters and measurement | Discovergy | Smart Meter | on request | Supported |
| Meters and measurement | Janitza | UMG 511 | on request | Supported |
| Meters and measurement | Janitza | UMG 604 | on request | Supported |
| Meters and measurement | Janitza | UMG 96 RME | on request | Supported |
| Meters and measurement | MICROCARE | SDM 630 (also identical SDM 630 from other manufacturers) | on request | Supported |
| Meters and measurement | PG-Plus | UMD96 | on request | Supported |
| Meters and measurement | PG-Plus | UMD97 | on request | Supported |
| Meters and measurement | Schneider Electric | Acti9 Smartlink | on request | Supported |
| Meters and measurement | SMA | Sunny Home Manager 2.0 (integrated meter) | on request | Supported |
| Meters and measurement | SOCOMEC | Countis E14 | on request | Supported |
| Meters and measurement | SOCOMEC | Countis E23, E24, E27, E28 | on request | Supported |
| Meters and measurement | SOCOMEC | Countis E34 | on request | Supported |
| Meters and measurement | SOCOMEC | Countis E44 | on request | Supported |
| Meters and measurement | SOCOMEC | Diris A10 | on request | Supported |
| Meters and measurement | SOCOMEC | Diris A14 | on request | Supported |
| Meters and measurement | SOCOMEC | Diris B30 | on request | Supported |
| Meters and measurement | TQ-Systems | EM 300 | on request | Supported |
| Meters and measurement | Weidmüller | 525 | on request | Supported |
| Power plant controllers and grid connection | Apollo | Apollo power plant controller on WAGO hardware (certified) | on request | Field-tested |
| Controllable relays and loads | KMtronic | Relay board with 4 or 8 channels | Modbus TCP/RTU | Supported |
| Controllable relays and loads | KUNBUS | Revolution Pi Digital IO Module | on request | Supported |
| Controllable relays and loads | Shelly | Shelly 2.5 | on request | Supported |
| Controllable relays and loads | Shelly | Shelly Plug S | on request | Supported |
| Controllable relays and loads | WAGO | 1-channel relay output 750-523 | via fieldbus coupler 750-352 | Supported |
| Controllable relays and loads | WAGO | 2-channel digital input 750-400 | via fieldbus coupler 750-352 | Supported |
| Controllable relays and loads | WAGO | 2-channel digital output 750-501 | via fieldbus coupler 750-352 | Supported |
| Controllable relays and loads | WAGO | Fieldbus coupler 750-352 | Modbus TCP | Supported |
| Dynamic electricity tariffs | aWATTar | HOURLY | on request | Supported |
| Dynamic electricity tariffs | Corrently | Electricity price forecast | on request | Supported |
| Dynamic electricity tariffs | Tibber | Dynamic tariff | on request | Supported |
| Interfaces and data services | InfluxData | InfluxDB | Time series database | Supported |
| Interfaces and data services | open standard | 1-Wire | 1-Wire | Supported |
| Interfaces and data services | open standard | M-Bus | M-Bus | Supported |
| Interfaces and data services | open standard | Modbus RTU | Modbus RTU | Supported |
| Interfaces and data services | open standard | Modbus TCP | Modbus TCP | Supported |
| Interfaces and data services | open standard | MQTT | MQTT | Supported |
| Interfaces and data services | open standard | OCPP | OCPP 1.6, OCPP 2.0.1 | Supported |
| Interfaces and data services | open standard | OPC UA | OPC UA | Supported |
| Interfaces and data services | open standard | REST-API (JSON) | JSON/REST | Supported |
| Interfaces and data services | open standard | SunSpec | SunSpec over Modbus | Supported |
| Interfaces and data services | open standard | Websocket (JSON) | JSON/Websocket | Supported |
No entry found. Just ask us – we usually connect devices that are not listed as part of a project.
As of November 2026, continuously extended.