Grid tariff reform AgNes: what changes for your site? Check now →
← All articles
Energy news · 5 November 2026

§14a EnWG: how to integrate controllable consumer devices properly

Controlling heat pumps, wallboxes and battery storage in a grid-friendly way: obligations, modules and savings under § 14a EnWG in Germany at a glance.

In short: Since 1 January 2024, grid operators in Germany may temporarily throttle new heat pumps, private charging points, air-conditioning units and battery storage systems rated above 4.2 kW when the grid is at risk of overload – but never below 4.2 kW and never switch them off completely. In return, grid charges are reduced. If you control several devices via an energy management system (EMS), you keep control over which device receives how much power and when.

What § 14a EnWG is about

Heat pumps and electric vehicles shift a great deal of load into the low-voltage grid. So that grid operators can still connect these devices quickly, the Bundesnetzagentur (Federal Network Agency, BNetzA) redefined the rules under § 14a EnWG (Energiewirtschaftsgesetz, Energy Industry Act) in November 2023 (determinations BK6-22-300 on control and BK8-22/010-A on grid charges). They have applied since 1 January 2024.

The trade-off is simple: the grid operator may no longer refuse or delay the connection of new heat pumps and private charging facilities by pointing to possible local overloads. In exchange, in an emergency it may throttle the power these devices draw for the duration of the overload. Complete disconnections are no longer permitted.

Which devices are affected

Controllable consumer devices are newly connected devices in the low-voltage grid with a power rating of more than 4.2 kW, in particular:

Smaller devices below 4.2 kW are not covered.

What the grid operator may – and may not – do

Minimum power of 4.2 kW. Even when throttled, every device must be able to draw at least 4.2 kW. A heat pump therefore keeps running and a wallbox keeps charging – just more slowly. For large heat pumps and air-conditioning units above 11 kW, a scaling factor applies: the minimum power is then 40 % of the connected load.

Only in the event of an actual overload. Control is grid-oriented, i.e. it only takes place when a section of the grid is genuinely at risk of overload, and only for as long as necessary.

Preventive control as a transitional measure. Where the grid operator does not yet have the technical means for grid-oriented control, it may control preventively if its grid planning suggests that an overload is likely. This is limited: for no more than 24 months from the first preventive control in the grid area and for up to two hours a day, again with at least 4.2 kW.

The three modules: how grid charges are reduced

In return for being controllable, operators receive a reduced grid charge. They can choose between three modules:

ModuleHow it worksRequirement
Module 1Flat-rate annual discount; depending on the grid area, according to the BNetzA around 110 to 190 euros grossno separate meter required
Module 2The energy charge component of the grid charge for the device is reduced by 60 %separate meter for the controllable consumer device
Module 3Time-variable grid charge with three price levels (peak, standard and off-peak tariff), which grid operators have had to offer since April 2025only in combination with Module 1, smart metering system

The exact amounts and time windows are set out in your grid operator’s price sheet.

Module 1 or Module 2?

As a rule of thumb: the more electricity the device consumes, the more likely Module 2 is to pay off. A simplified example using assumed values:

Module 2 also involves costs for the separate meter and, where necessary, modifications to the meter cabinet. With low consumption – for example a wallbox that is rarely used for charging – Module 1 is often the simpler and better choice. Do the calculation using your grid operator’s figures.

Module 3 pays off if consumption can be shifted flexibly into low-cost time windows – which is exactly what a battery storage system or a heat pump with a buffer tank and intelligent control can do.

Several devices: control via an energy management system

If several controllable devices are connected to one grid connection – for example a heat pump, a wallbox and a battery storage system – the grid operator does not have to control each device individually. It can pass a total power limit to an energy management system. The EMS then ensures that the combined load of all devices stays within this limit.

In this case, the guaranteed minimum power is calculated as 4.2 kW multiplied by a simultaneity factor that is graduated uniformly nationwide, because with each additional device it becomes less likely that all of them need full power at the same time.

The advantage for operators: the EMS decides for itself how the available power is distributed. The heat pump can be given priority, the electric car charges more slowly during the throttled phase, and the battery storage bridges the gap with its own energy. Without an EMS, each device would be limited across the board.

The technology behind it

Control commands are transmitted via the smart metering system: the smart meter gateway receives the grid operator’s signal, and a control box forwards it to the device or the EMS. Where the technology is not yet in place, the grid operator may, as a transitional measure, also use older control technology that is not connected to a smart metering system.

Existing installations

What this means for companies and apartment buildings

Commercial properties and apartment buildings often combine several controllable devices: wallboxes in the underground car park, heat pumps, a shared battery storage system. This is where an EMS shows its strengths:

  1. Complying with requirements: the grid operator’s power limits are implemented automatically, without individual devices being hard-limited.
  2. Using time-variable grid charges: with Module 3, the EMS shifts charging processes and heat generation into low-cost time windows.
  3. Integrating PV and storage: your own solar power and stored energy cover load peaks, especially when grid capacity is tight.

Apollo EMS implements the requirements of § 14a EnWG and controls battery storage, PV and charging points together – from apartment buildings to commercial properties. Find out more under Energy management.

Frequently asked questions

Can the grid operator switch off my heat pump?

No. Complete disconnections are no longer permitted. The grid operator may only temporarily throttle the power drawn when there is a risk of overload; at least 4.2 kW always remains available.

Does § 14a also apply to my battery storage system?

Yes, if it can charge from the grid at more than 4.2 kW. Control applies to the power drawn from the grid, not to feed-in.

Which module applies if I do not choose one?

According to many grid operators, Module 1 is then applied. You can apply to switch to a different module through your grid operator or your supplier.

Do I need a smart meter for § 14a?

A smart metering system with a control box is intended for grid-oriented control, and likewise for Module 3. Until the technology has been installed, grid operators may use older control technology as a transitional measure.

Is an EMS worthwhile for just one device?

For a single wallbox, usually not on account of § 14a alone. However, as soon as a heat pump, wallbox, PV and battery storage come together, an EMS distributes the available power sensibly and takes advantage of low-cost time windows.

Sources

As of November 2026. This article does not constitute legal advice; the determinations of the Bundesnetzagentur and your grid operator’s price sheet are authoritative.

Contact

How would you like to talk to us?

Your details
Please choose a day

Write to us